120V White LED Strip Light - Plug and Play - High CRI - IP65 Water Resistant - Dimmable - 5m / 25m


Austin
Account Manager
Empower Your Business
Exclusive benefits & tailored support await you.
Sign up for a Commercial Account today!
Features
- Easy plug-and-play installation
- Max Run of 164 ft. (50 m)
- 0-100% TRIAC dimmable
- Delivers 384 lm/ft with 24 LEDs/ft
- IP65 Water-resistant construction
- 90+ CRI provides vibrant color rendering
Loading recommendations...
Overview
The 120V White LED Strip Light offers a versatile solution for both indoor and outdoor applications. Featuring TRIAC dimmable technology, it allows for precise brightness control, while its 90+ CRI ensures vibrant and accurate color rendering. Available in 3000K, 4000K, and 5000K color temperatures, this tape light can match a variety of settings. With IP65 waterproof construction, it is suitable for wet locations, making it ideal for under-cabinet lighting near a sink, outdoor accent lighting, and other residential applications. Its plug-and-play design simplifies installation, available in both 16.4 ft (5 m) and 82 ft (25 m) lengths.
Product Details:
- Max Run: up to 164 ft (50 m)
- 17mm Strip Width
- TRIAC Dimming
- 2-Prong Wall Plug Connector
- ETL Listed
- 5-year warranty
- Accent Lighting
- Ambient Home Lighting
- Cove Lighting
- Exhibitions
- Retail Shops
- Trade Shows
- Under-Cabinets
LED Strip Lights FAQs
Specifications
| Ambient Operating Temperature | -20 to 45 °C (-4 to 113 °F) |
|---|---|
| Certifications/Compliance | ETL Listed |
| CRI | 90+ |
|
Current Draw per Foot
Current Draw per Foot
Current Draw Per Foot is used to size power supplies, normally converted to watts per foot. This is equated using total wattage divided by number of linear feet. Current draw per foot is the amount of current consumed by an LED or LEDs in an electrical circuit per linear foot at a specific voltage, measured in milliamps (mA) or watts (W).
|
36mA |
| Dimmable | Yes |
| Dimmer Type | TRIAC |
| Efficacy | 90 lm/W |
|
Environmental Rating
Environmental Rating
Suitable for Dry Locations This marking indicates that you can use the light or component in a location not normally subject to dampness. This may include locations exposed to temporary dampness, such as a building under construction, provided that ventilation is adequate to prevent moisture accumulation. Use these fixtures in living rooms, bedrooms, offices, hallways, and similar areas. The marking may be "SUITABLE FOR DAMP LOCATIONS" or "DRY LOCATIONS ONLY."Suitable for Damp Locations Fixtures marked “SUITABLE FOR DAMP LOCATIONS” or “SUITABLE FOR WET LOCATIONS” can be installed in damp locations. A damp location is an exterior or interior location regularly or occasionally subject to moisture condensation on or around electrical equipment. It includes partially protected places such as covered patios and porches. Damp locations include any regularly muggy or humid area, such as above a kitchen sink or stove, and appropriately vented bathrooms near the tub or shower.Suitable for Wet Locations Fixtures and components marked "SUITABLE FOR WET LOCATIONS" can be installed in wet or damp locations. A wet location is anywhere water or other liquids may drip, splash, or flow on or against electrical equipment. A light marked "SUITABLE FOR WET LOCATIONS" may have additional markings that tell where and at what height it can be safely mounted. Uncovered outdoor areas like decks, gazebos, walls, and typical landscape lighting sites all fall under the heading of wet locations. |
Suitable for Wet Locations, Waterproof |
| Finish | White |
| Input Connection Type | 2-Prong Wall Plug |
|
IP Rating
IP Rating
![]() |
IP65 |
|
LED Beam Angle
LED Beam Angle
Beam angle is used to express the angular dimension of light emitted from its source. The narrower the beam angle the more focused the light. Comparing two lights with the same lumen output, one with a 30° beam angle and another with a 90° beam angle, the 30° will appear brighter compared to the 90°, while the 90° will illuminate a larger area. Lights with a symmetrical output may have a beam angle expressed with a single value (e.g. W 120° x H 120° will be shown as 120°). Bulbs will typically have a single value expressing the outward beam angle projected at 360° (e.g. 120° is actually 360° x 120°).
|
120° |
| LED Density | 24 LEDS/ft |
| LED Chip Type | 2835 SMD |
| LEDs per Segment | 8 |
| LED Lifetime | 36000 Hours |
| Lumens Per Foot | 384 lm/ft |
|
Max Run (Class 2)
Max Run (Class 2)
The Max Run of an LED strip is dependent on two things, voltage and density. 24 volt strips in most instances will give you a longer run than a 12 volt strip. However the LED density of the strip will have an effect on the maximum run. If your install needs to extend beyond a strips Max Run additional power feeds can be run back to your power supply. ![]() ![]() |
164 ft (50 m) |
| Minimum Cut Length | 100mm (3.9in) |
| Operating Voltage | 120 VAC |
| Series | HighLight |
| Strip Width | 17mm (0.66in) |
| Wattage | 70 Watts |
| Wattage per Foot | 4.3 W/ft |
| Wire Length | 18 in. |
| Part NO |
Color Temperature
Color Temperature
![]() Correlated Color Temperature is the hue, or tint of white to expect from a light source and is measured in kelvin. Lower numbers give off a warmer white that is closer to candle light, and is good for relaxed and cozy spaces. Higher numbers give off a cooler white light that will appear more blueish. While values to the middle of the spectrum give off a more neutral or natural white light that is similar to daylight. |
Current Draw
Current Draw
Current draw is calculated using the following formula: W/V = A, where W = the amount of power your light needs (wattage), V is the electrical system voltage (e.g., 120V AC), and A = amps. An ampere or amp (A) is the standard unit for electrical current. A milliamp (mA) equals one-thousandth of an amp, or 1000 mA is equivalent to 1 A.
Choosing LED fixtures with the correct amperage ensures safe and proper operation, preventing damage or injury. We recommend having all electrical components and fixtures installed by a certified professional electrician or lighting technician in compliance with all relevant standards and regulations. |
LED Color | Length |
|---|---|---|---|---|
| STACD-A30K90-C8D-14S25M-120V | 3000K | 2.9 A | Warm 3000K | 82 ft (25 m) |
| STACD-A30K90-C8D-14S5M-120V | 3000K | 580 mA | Warm 3000K | 16.4 ft (5 m) |
| STACD-A40K90-C8D-14S25M-120V | 4000K | 2.9 A | Natural 4000K | 82 ft (25 m) |
| STACD-A40K90-C8D-14S5M-120V | 4000K | 580 mA | Natural 4000K | 16.4 ft (5 m) |
| STACD-A50K90-C8D-14S25M-120V | 5000K | 2.9 A | Cool 5000K | 82 ft (25 m) |
| STACD-A50K90-C8D-14S5M-120V | 5000K | 580 mA | Cool 5000K | 16.4 ft (5 m) |
Accessories & Power Supplies
Reviews
Review Guidelines
Industrial Commercial Lighting reads and approves all reviews before listing them on the website. Below you will find a list of reasons that can result in your review being rejected.
- Review text does not pertain to the product
- Photos are not related to the reviewed product
- Any violation of laws and/or copyrighted material
- Unrelated hyperlinks/URLs







